
Flexible
200W Lightweight Flexible Solar Panel
A lightweight 200W flexible format for selected curved surfaces. Review substrate, permitted bending and ventilation before installation.
View specifications →
SOLAR MODULES
Auriva Energy is a flexible solar panel manufacturer in China for RV, marine and OEM projects. Review bending limits, dimensions, electrical data and sample requirements.
Reference module range · 10–400 WFlexible solar panels can suit selected mobile applications. Choose the module together with the mounting method, ventilation requirements and surface conditions.
Confirm model ratings and installation details against the selected product documentation.
APPLICATION & SELECTION
RV roofs and other mobile installations where the selected model is suitable.
A flexible module enquiry begins with the surface geometry and installation method. A lightweight or bendable format may suit selected vehicle roofs and integrated products, but the allowable curvature belongs to the complete module construction.
Describe the direction and radius of the curve, the supporting surface and whether the panel remains fixed or moves during use. These details help define a suitable substrate, cable exit and mounting approach without assuming that every flexible panel is foldable.
AURIVA ENERGY · PRODUCT SERIES
Choose a series, compare power configurations and review the complete specification on its product page.

Flexible
A lightweight 200W flexible format for selected curved surfaces. Review substrate, permitted bending and ventilation before installation.
View specifications →
Flexible
A black lightweight module selection. Confirm the final construction drawing, dimensions and weight before specifying your installation.
View specifications →
Flexible
100W and 200W N-type flexible module configurations for compact solar integration and model-specific shade review.
View specifications →No series match. Reset the filters or share your requirements.
WHY THE FORMAT MATTERS
Provide a roof profile or dimensioned curved-surface drawing, rather than only an overall panel length and width.
Discuss the laminate finish, edge treatment and cable location with the surrounding product design.
Review adhesion or mechanical fixing together with support, ventilation and service access.
KEY PARAMETERS
These are family-level selection details. Exact ratings, dimensions and supplied components are confirmed against the selected model documents.
Family reference range
10–400 W
| Parameter / design input | What to confirm |
|---|---|
| Rated power (Wp) | Select output for your charging requirement. |
| Dimensions & weight | Provide the available installation envelope. |
| Permitted curvature | Confirm the selected model's installation limits. |
| Mounting & ventilation | Follow the model-specific installation instructions. |
| Electrical values | Confirm Voc, Isc, Vmp and Imp before system design. |
MODULE CONFIGURATION
Include these inputs in the model and drawing review.
| Parameter / design input | What to confirm |
|---|---|
| Front layer & substrate | Request the selected laminate stack, surface material, overall thickness and substrate specification. |
| Permitted curvature | Confirm the minimum bending radius, direction and whether the stated limit applies to fixed installation or repeated movement. |
| Mounting interface | Specify the supporting material, intended adhesive or fixing method and required service access. |
| Module electrical data | Request Pmax, Vmp, Imp, Voc and Isc for the exact size and cell configuration. Rated watts alone do not establish equipment compatibility. |
| Array & connected equipment | Provide series / parallel layout and the controller, inverter or power-station model. Check its PV voltage window, startup requirements and current limits. |
| Temperature & test conditions | Review temperature coefficients and the intended operating environment. Nameplate values are reference test values; installation output varies with site conditions. |
| Cable exit & strain relief | Agree exit location, connector, cable length and protection against mechanical stress. |
INSTALLATION & VALIDATION
Use the selected model’s instructions and an agreed project design.
Provide a cross-section or template of the surface, including compound curves, steps and edges.
Follow the selected module instructions for handling, support, ventilation and mounting. Confirm whether the panel may be walked on.
Keep cable exits and connections clear of high-stress areas; plan routing and fastening with the mounting design.
SHADE & SYSTEM MATCHING
Partial shade can change a module’s operating point. Bypass paths may allow current around an affected cell group, while reducing the module’s available output. The response depends on the electrical layout and the connected equipment.
Vents, aerials and rooftop equipment.
Narrow shadows that move across the deck.
Structures near the intended installation.
Illustrative shadow positions only. These sketches do not show a model’s cell wiring, bypass topology or measured output.
CUSTOM EVALUATION OPTION
For installations with recurring shadows, include a shade review in the module enquiry. A shade-tolerant electrical configuration can be discussed as a custom requirement; availability, bypass layout and performance must be confirmed for the proposed model and test conditions.
Discuss shade requirementsShade tolerance does not guarantee full rated output under shade. Prioritize a suitable layout and validate the complete system.
TECHNICAL RESOURCES
Download available resources or request model-specific documentation.
Selection guides explain what to confirm. A model datasheet or installation manual defines the chosen product.
PRODUCT FAQ
Clear answers for your specification and quotation.
Do not assume repeated folding is permitted. Fixed curvature and repeated movement are different design requirements. Use only the bending and handling limits stated for the selected model.
The surface material alone does not define the complete panel limit. Request the module construction, permitted radius and mounting instructions before selecting a curved installation.
Wattage describes module power under stated test conditions. Daily energy also depends on sunlight, orientation, temperature, shading and system operation. Provide the location and daily loads so the project can be assessed.
Ask for the model datasheet, dimensioned drawing, electrical values and installation instructions. Confirm the scope of any test report, certification or warranty against the exact model, destination and purchase agreement.
A CLEARER PRODUCT ENQUIRY
Send your application and requirements to Auriva Energy for the next product discussion.
Prepare a product enquiryDownload RFQ worksheet
Solar Panels
Framed solar modules for rooftops, vehicles and fixed installations.
Reference module range · 5–705 WExplore range
Solar Panels
Foldable modules and portable solar charging for travel and outdoor use.
Reference module range · 35–480 WExplore range
Solar Panels
Slim framed modules for vehicles, balconies and compact roof layouts.
Reference module range · 20–300 WExplore rangeYOUR NEXT ENERGY PROJECT
Share your application, market and requirements.
MODULE SELECTION & OEM REVIEW
Flexible solar panels need a defined supporting surface and a model-specific bending limit. Fixed curvature is different from repeated folding. Review surface preparation, ventilation, bonding and cable strain relief before selecting the module.
Provide the curve direction and radius, and confirm the permitted bend limit.
Describe the substrate, operating conditions and ventilation arrangement.
Confirm power, voltage, connector, cable length and junction-box position.
BEFORE YOUR FIRST ORDER
Sample quantity, minimum order, sample cost and customisation depend on the proposed model. Request these with your quotation.
Provide the quantity and destination. Confirm readiness, shipping terms and delivery schedule in writing before ordering.
Review the exact model datasheet, applicable supporting documents and written warranty terms.
Documents ↗ Warranty ↗